Septic systems firm in Valley Springs

Valley Springs, CA septic inspections firm? When it rains and the ground gets saturated, ground water can enter the system. This can cause leach field saturation as additional water is introduced to the tank through I&I which can be more than your leach field can absorb. You will see water ponding over your leach field or running above the ground. On dosing systems, the computer can sound audible alarms. I&I also lets red worms make it through into your system filter pod (if you have this type of system). The worm’s waste, called “castings” clog the filters causing ponding and ruins the pretreatment your system was designed for.

Repair leaky faucets. Water that is wasted through leaky taps puts a strain on your septic tank system (not to mention, it also increases your water bill!). Be sure to repair leaky tap right away. Don’t pour household chemicals down the drain. Dispose of motor oil, antifreeze, paint, pesticides and potent cleaners properly. They should never be poured down the drain because they kill bacteria that breaks down solids in your septic tank.

Septic cleaning products are available to break up blockages in the pipes. Tree roots are a common blockage in older septic systems. Root killers, available at local hardware stores, can be used routinely to help prevent their spread. A pump tank is controlled by either control floats or timer controls. It also requires electricity to operate so limit water use if there is a power outage. If the capacity in the tank is too high or too low or a malfunction occurs, most systems are equipped with a red alert alarm (located on the top of the control panel) to warn the homeowner. Limit water use through a couple of pump cycles (10-15 hours) to see if the alarm goes out on its own. If the red light goes out, the system is working properly. If not, continue to limit water use and consult a professional septic service provider for advice.

A good site to visit for several educational videos regarding septic systems can be found on Washington State’s Department of Health On Site Sewage Systems Home Owner Education Page. The Full video course is 5 chapters and runs 19:02 minutes. You can watch the individual chapters by themselves which range from 2:29 to 6:57 minutes in length. Chapter 3 – Types of Septic Systems is 6:57 minutes and goes over most of the systems described on this page. Septic Systems are Engineered by a Licensed Engineering Company. We at Foothill Sanitary Septic highly recommend Cal State Engineering in Jackson, CA as they are the best. Find more information at foothill sanitary california.

Lush vegetation in the drain field area or wet spots in your lawn are often signs of an overloaded septic system. If there are gurgling sounds in the plumbing, slow draining fixtures or the plumbing backs up, call for service immediately. The quicker a problem is diagnosed and resolved, the more likely you are to avoid a complete system failure. Even with good maintenance, no septic system lasts forever. If your tank is 20 years old or older, you can anticipate needing repairs, if not a complete replacement. If you don’t know the age of your septic tank, schedule an inspection. This assessment can give you information about what to expect from the tank’s performance during the next few years.

Foothill Sanitary started in 2001. A family owned business with a strong work ethic and true integrity. Our desire is to help our customers with their septic and portable toilet needs. We take the time to educate our customers about their septic systems so that they understand its function and how to prolong its life span. Our portable toilets are cleaned and disinfected very well so that you always have a nice usable unit.

The home’s sewer line drain pipe needs to slope 1/4 inch per foot downhill to the inlet side of the septic tank and the outlet pipe needs to flow downhill at least 1/8 inch per foot downhill to the leach field, where the septic tank effluent enters a manifold or distribution D box. Beyond the manifold or D box the leach field trenches (for an Infiltrator chamber system) are excavated perfectly level at a depth of at least seven inches below the grade of the manifold pipes or D box (for chambers). And covered with at least one foot of soil atop the trench or chamber. Trenches can be deeper, if the site dictates, but rarely more than three feet below finish grade. Read additional information at this website.